Section 13 - Mechanics Of Programming
13–3
Loading Factory Defaults
The control panel is shipped from the factory loaded with its factory defaults. To reload the
factory defaults at any time, enter the Programming mode, press
✱
97, then exit the
Programming mode.
Do not press
✱
97 to load defaults if any programming has been done previously—data already
programmed into the system will be changed!
This includes the primary and secondary
subscriber account numbers (fields
✱
43 and
✱
44), which will be set to their factory defaults
also.
✱
96 resets all the subscriber account numbers and CSID in preparation for an initial
download.
Programming System Setup Fields
The following program fields must be programmed before doing any zone programming:
✱
22 RF SYSTEM
0
Enter
1
if 5881/5882 RF Receiver is being used; enter
0
if no receiver is being used.
Default is
0
(none).
✱
25
WIRED ZONE EXPANSION
0
Use this field to select the type of expansion unit being used, as follows:
0 = none; 1 = 4219; 2 = 4229; 3 = 4204. Default is
0.
Exiting the Programming Mode
✱
99 allows re-entry into the Program mode using [Installer Code] + 8 0 0.
✱
98 prevents re-entry into the Programming mode using the Installer code.