6–1
SECTION 6
Wireless Expansion
(5800 System)
••••••••••••••••••••••••••••••••••••••••••••••••••
In This Section
About Wireless Expansion
Installing the 5881/5882 Receiver
Installing the 5800TM Module
About Jam Detection and Reporting
5800 Series Transmitters
Installing 5800 Series Transmitters
••••••••••••••••••••••••••••••••••••••••••••••••••
About Wireless Expansion
In
addition
to its basic wired zones, the
SL150
control supports up to 30
wireless zones
using
an appropriate 5881 (5882 in Canada) type RF receiver. The actual number of zones
supported depends on whether you are using a wired zone expander module.
For example
: If
you are using only four of the wired expansion loops, a
5881H (5882H in
Canada)
RF receiver could add 26 RF zones to the system, using any unused zone
numbers
10–39, for a combined total of 30 wired and wireless expansion zones.
The receiver can detect signals from
wireless transmitters
within a nominal range of 200
feet.
RF Receiver No. of Zones
5881L/5882L up to 8
5881M/5882M up to 16
5881H/5882H up to 30
Receiver Supervision
The receiver is supervised. The following conditions will cause a Trouble report to be
generated and
CHECK
and
ZONE 09
messages to be displayed:
If communication between the panel and the receiver is interrupted.
or
If
valid
RF signals from at least one supervised wireless transmitter are not received
within 12 hours.
House Identification
If you are using a 5804BD, 5827, or 5827BD Wireless Keypad with the system, you must
program a House ID Code (01–31) in field
24 to establish proper communication, and the
keypad must be set to the same ID.
House ID “00” disables all wireless keypads.