Security Link SL150 Průvodce řešením problémů Strana 10

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 144
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 9
SL150 Installation and Setup Guide
1–2
Security Codes
One Installer code for entire system (user 1)
•One Master code
for entire system
(user 2)
12 Secondary User
codes
(users 3–14)
One Babysitter code (user 15).
One Duress Code (user 16).
Baby-sitter Code:
A special code that can only be used to disarm the system if that particular
code (or the installer code) was used to arm it. Generally assigned to a babysitter or cleaner.
Duress Code:
An emergency code that, when entered by
any
user, will send a silent duress
message to the Central Station.
Note:
A report code must be programmed otherwise it will be
reported as user 16 only.
Keypad Panic Keys
Up to 3 programmable panic key pairs provided
Designated as zones 95, 96, 99
Activated by wired and wireless keypads
Distinguished by subscriber ID number.
Zone Monitor Features
The control will sense a high resistance or short in the loops on hardwired zones
2–8 if present, and will display a trouble (CHECK) message (rather than an alarm)
for the affected zone when the system is in the disarmed mode. The system cannot
be armed as long as this condition is present.
• Also sends a Trouble message to the Central Station when the system is in the
disarmed mode.
Exit Error False Alarm Prevention Feature
• Enables the system to determine the difference between an actual alarm and an
alarm caused by leaving an entry/exit or interior zone open after the Exit Delay
expires. If not disarmed in time, an alarm will sound and an Exit Error report will
be sent to the Central Station.
An exit alarm condition will also occur if an entry/exit or interior zone re-opens
within 2 minutes after the end of an Exit Delay.
Exit Restart Feature
The system contains an Exit Restart feature which allows the user to restart the
exit delay at any time when arming in the STAY or INSTANT modes by simply
pressing the [
] key. This is useful if the user wishes to open the entry/exit door to
let someone in after arming the system, and avoids having to disarm the system
and then re-arm it again. This feature allows only one restart of the exit delay
time for each arming session.
This feature will be enabled when an “8” or greater
value is entered in field
91.
Optional Output Relays and Powerline Carrier Devices (X10 type)
Maximum of 4 Output Devices
Up to 4 relays using one
4204
Relay Module
Up to 2 relays using one 4229 Zone Expansion/Relay Module
Up to 8 Powerline Carrier devices (you must subtract the number of relay outputs
actually used by the 4204 or 4229 modules, if used)
Actions programmable to respond to zone activity or manual keypad entries.
Powerline Carrier devices require the use of the optional 4300 Transformer Module instead of the
supplied 1321 AC Transformer.
Zobrazit stránku 9